CRA · CASE STUDY

One component in three offerings

Find out what changes the offer as a medical device, device or spare part for classification.

PRODUCT
CONFORMITY
MAINTENANCE

Starting position and test order

A manufacturer offers a device for which the medical purpose and applicability of the Medical Devices Ordinance are documented in the sample. He uses the same assembly in a separately offered, networked data logger for general building data.

As a third offer, he exclusively sells the assembly as an identical spare part for an existing variant. The original specifications and the actual specifications used are completely consistent in the exercise.

Compare test data and consequences

  • Medical product

    Scale
    MDR applies to the specific product
    Observation
    In the case of explicit evidence
    Follow
    Use Art. 2 (2) CRA
  • General network logger

    Scale
    Separate purpose and distribution
    Observation
    For building data
    Follow
    Execute CRA classification separately
  • Identical spare part

    Scale
    Only identical exchange and same specification
    Observation
    Both characteristics are comprehensible
    Follow
    Use Article 2(6) CRA

A range of products per legal scope

The MDR device and the identical spare part have their own exceptions in case of a specific case. The network logger is assessed separately as being covered by the CRA.
The MDR device and the identical spare part have their own exceptions in case of a specific case. The network logger is assessed separately as being covered by the CRA.

Document the purpose, offer and appropriate legal basis for each unit separately.

Edit the test step by step

  1. The three market offers with their purpose

    Arrange each unit to own description, marking and provision.

    Testable evidence Three clearly separated product items.

    Acceptance criterion
    Record the identifier, marketed configuration and intended purpose for each offering.
    Evidence
    Evidence list recording original source, version, documented mapping and owner.
  2. The specific conditions of the exemption are confirmed

    Link the first product with the relevant medical product proof. Compare purpose and specification of the spare part.

    Testable evidence Two separate and documented exceptions in the pattern.

    Acceptance criterion
    Record the evidence for the medical device and the spare-part specification reconciliation as separate decisions.
    Evidence
    Evidence list recording original source, version, documented mapping and owner.
  3. Confirm the remaining CRA decision and new test grounds

    Check the data logger offered separately using the application area. Submit a new test with changed offer or technical specifications.

    Testable evidence Data logger recorded and verifiable verification order according to CRA.

    Acceptance criterion
    Document the applicability decision for the separately marketed logger with factual evidence and a trigger for reassessment.
    Evidence
    Evidence list recording original source, version, documented mapping and owner.

Worked decision and negative test

Decision in case

Medical and spare parts are excluded for different reasons. The networked data logger is to be classified separately with its actual purpose and offer.

Check with new delivery versions whether the assessed exception bears the modified characteristics and further provision. Secure for each product the confirmed deadline and the concrete basis.

Counter-sample and impact

Change the assembly for spare parts sales so that the production specifications differ and it is marketed as a functional general device. The previous exception for identical replacement does not bear this new provision. Check the scope again.

Audit record
Comparison of the original finding and retest showing the changed condition, observed effect and closure decision.

Templates and worksheets

  • Product border and common proof of conformity

    Compare legal reference, version and independently required documents per product range.

    Outcome Classification and approval note with applicable basis and appropriate explanation.

    Read the instructions

    Fictional example The networked packaging machine has a confirmed access certificate. The machine effect is open.

    1. Identify the starting situation Justification of actual offer, purpose and possible exceptions
    2. Run the test to assign supporting documents per act and actual version.
    3. Secure decision and evidence Ensure the appropriate procedure, joint declaration and decision where appropriate.

Official sources

First check for this task

Other official references1

What depends on your result?

  • Clear exceptions and technical law per product

    Transfer the same test criteria to your own product and save the different starting data.

    View the guide
  • Product scope and remote processing

    For a further recorded offer you determine product function, required remote processing and delivery.

    View the guide