CRA · IMPLEMENTATION GUIDE

Maintain conformity in production

Compare production profiles, embossed product status and output testing across lines and batches.

PRODUCT
CONFORMITY
MAINTENANCE

What you decide and prove

Compare the released product stand with the actual manufacturing and delivery processes used. Serial compliance requires a reference to hardware, software, configuration and visible product identification at output.

Arrange changes to procedures, design or product characteristics to existing evidence. Also check changes in standards, common specifications or certification schemes on which the previous statement of conformity is based.

If you do not have a fault, capture the actual affected row. Set a reliable delimitation for unaffected batches. Secure the output sample after correction and mandatory release for the modified line.

Edit the test step by step

  1. Track the confirmed initial profile to line

    Open the statement for both issues and compare firmware and actual start profile per device.

    Testable evidence Line-by-line assignment of the twelve output units.

    Acceptance criterion
    A second reviewer can follow the statement to the original evidence and the version checked. Record the evidence identifier or file reference with the decision.
    Evidence
    Evidence list recording original source, version, documented mapping and owner.
  2. The two deviations are correctly limited

    Return the serial identifiers to the station and the profile used there. Check independently whether further batches are affected.

    Testable evidence The extent of the error, not the general nature of the release.

    Acceptance criterion
    The item under review and the documents refer to the same approved version. Record obsolete evidence as a separate discrepancy.
    Evidence
    Versioned mapping of item, source and approved version with any discrepancy recorded.
  3. The corrected series produce controlled

    Repeat the output sample on the changed line and check the start profile before releasing the specified inventory.

    Testable evidence Six current post-test documents or a well-founded, open series.

    Acceptance criterion
    Reconcile expected and observed records using the same identifier. Resolve missing, duplicate or unmatched records individually.
    Evidence
    Reconciliation sheet recording the identifier, expected and observed mapping, source and finding.

The firmware is correct and two devices get the wrong start profile

A manufacturer of radio meters complements the production with a second line. According to the manufacturing instructions, both lines deliver version 4.3 with a limited delivery profile. The new line uses another station for the test run for the preparation of the device profile.

Six devices of the previous line correspond to the release. In the new line two out of six first editions differ in profile setting, although all devices report the same firmware. The output file contains the unique serial identifiers.

What you'll find out in the case

The series decision with demarcated inventory, measure and verified output sample per line.

Editing the Practice Case

Templates and worksheets

  • Sample per product profile and series

    Compare planned quantities, actual valid samples and passed cases per delivery profile.

    Outcome Tested sample size with open profiles and scheduled repetition.

    Read the instructions

    Fictional example Six out of six samples are in place.

    1. Identify the starting situation Deriving groups and occasions from product and delivery stock.
    2. Run the test Determine the validity and result per group.
    3. Secure decision and evidence Sample open profiles in the affected line or environment.

Official sources

What depends on your result?

  • Clear type modification with notified body

    If the modified structure may affect the approved version or conditions of the certificate, you shall involve the competent notified body.

    View the guide